微波EDA網(wǎng)-關(guān)于我們 微波EDA網(wǎng)-出版的圖書專著 微波EDA網(wǎng)培訓(xùn)課程列表 射頻工程師養(yǎng)成培訓(xùn)學(xué)習(xí)教程
  • 1
  • 2
  • 3
  • 4

Deleting Solution Data

You can use Clean Up Solutions to selectively make deletions, or remove all solutions from the results.

To use Clean Up Solutions:

1. Click HFSS>Results>Clean Up Solutions.

The Clean Up Solutions dialog box appears.

[spacer]

2. Under Solutions, select whether you want to delete only fields data, only fields and mesh data, only linked data, or all solution data. Deleting all solution data erases all mesh, matrix, and fields data for all adaptive passes and frequency sweeps for the selected Variations.

By option, you can include linked data in the deletions.

Linked data can be mesh, field or some other post-processing data that the source design generated. The target design for the link caches these data internally to minimize the need to activate the source design.

3. Under Variations, select which solution data you want to delete:

• Select All Except Current Variation to delete all solution data that do not correspond to the current project and design variable values for the current design.

• Select All Variations to delete all solution data for the current design.

• Select Select to specify the variations you wish to delete. Click Variations to select the variations for deletion.

4. Click Do Deletions.

The solution data you selected are deleted. Any post processing reports or field overlays you created that included data you deleted will be marked with an X in the project tree. They will be invalid until new solution data are generated.

 

Related Topics

Monitoring the Solution Process

Deleting Reports