HFSS online help > Viewing Analysis Results for Optimetrics Solutions >
Viewing Results for Parametric Solution Quantities
To plot solution quantity results versus a swept variable's values on a rectangular (x - y) plot:
1. In the project tree, right-click the parametric setup for which you want to view the results, and then click View Analysis Result on the shortcut menu.
The Post Analysis Display dialog box appears.
2. If it is not already selected, select Plot as the view type.
3. Select the variable with the swept values you want to plot on the x-axis from the X pull-down list.
4. Only one sweep variable at a time can be plotted against solution quantity results. Any other variables that were swept during the parametric analysis remain constant.
Optionally, to modify the constant values of other swept variables, do the following:
a. Click Set Other Sweep Variables Value.
The Setup Plot dialog box appears. All of the other solved variable values are listed.
b. Click the row with the variable value you want to use as the constant value in the plot, and then click OK.
5. Select the solution quantity results you want to plot on the y-axis from the Y pull-down list.
The xy plot appears in the view window.
6. Right-click in the plot area to get the shortcut menu where you can set modify the plots display properties, print, copy to the clipboard, or export the data to a file.